{"en":"NWN-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower","zh-cn":"NWN-GS系列干湿混合式诱导通风闭式冷却塔"}

NWN-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower

NWN-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower

NWN-GS 
Dry-Wet Hybrid Induced Draft Closed Cooling Tower
Normal Model: NWN-GS
Cooling Tower Type: Counter Flow Closed Type
Air Ventilation:  Induced Draft ( Axial Fan Drive System)
Cooling Mode: Dry-Wet Hybrid Cooling
Heat Exchanger: Stainless Steel Heat Exchange Coil
Cooling Tower Body: Z700 Galvanized Steel (SUS304/316 or NWN-Armour anti-corrosion coating steel plate for option)

 

 


NWN-GS Series Dry-Wet Hybrid Induced Draft Closed Cooling Tower

The cooling system of NWN-GS series integrates the attributes of wet and dry cooling, delivering optimal cooling performance, minimal energy consumption, and water conservation across varying ambient temperatures. It is particularly well-suited for arid desert regions and harsh cold climates. Additionally, its forced draft system allows the low-noise operation and represents the optimal cooling solution for inadequately ventilated and noise-sensitive locations.

140x140

ADVANTAGE



 140x140

Dry-Wet Hybrid Cooling Mode
NWN-GS cooling tower has the capability to adapt its operational modes in response to fluctuations in ambient temperature.


Dry Cooling Mode
When the temperature falls below -10℃ or the output temperature is lower than the set point, the spray pump will cease operation and the cooling tower will switch to dry cooling mode. This minimizes water evaporation during cold seasons and provides ice water in certain working conditions as an alternative to refrigeration, resulting in water and energy savings.

Wet Cooling Mode
When the temperature exceeds a specific threshold (-2℃), or when the output temperature surpasses a predetermined level, the spray pump initiates operation, causing the cooling tower to function in wet cooling mode. Evaporative cooling guarantees substantial cooling capacity.
 



140x140




Minimized Water Contamination, High Thermal Efficiency, Reduced Operational Expenditure.


The counter-flow closed-loop cooling system maintains optimal heat transfer efficiency while ensuring pure media protection, substantially reducing both environmental contamination potential and operational water treatment costs.

 

 

140x140


Wide application range with exceptional scenario compatibility.


This system is ideally suited for industries with stringent cooling water quality requirements (e.g., electronics, pharmaceuticals), precise temperature control needs (e.g., chemical process cooling), or restricted water discharge capabilities—effectively mitigating the contamination risks associated with open-loop cooling. It maintains high heat dissipation efficiency even in hot/humid climates while significantly reducing water consumption and freeze damage in cold/arid regions. Particularly well-adapted to diverse climate zones like Northern China, it delivers reliable performance across extreme environmental conditions.



MAIN PARTS


140x140

High Efficient Axial Flow Fan

> Utilization of the cooling tower special aluminum alloy axial flow fan, forward type blade structure design, small wind resistance, big air volume, low noise, good performance, high efficiency.

> Streamline high-strength fan stack ensures airflow uniform through the fan inlet and outlet area, maximum reduce the energy consumption.

> Fan motor's protection class: IP55, Insulation class: F class. Options: Two-speed, VFD or anti-explosion motor.


 


Key Parts for Closed Circuit System And Dry-Wet Cooling Modes.

The fluid medium requiring cooling circulates through the
fin tube heat exchanger and stainless steel heat exchange coil within the closed circuit system, ensuring cleanliness, reducing water treatment and maintenance expenses, and conserving precious water resources while efficiently cooling.

Fin tube heat exchanger and stainless steel heat exchange coil are not only essential components of closed circuit systems, but also key elements of Dry-wet cooling modes.
 

140x140


 

Finned Tube Heat Exchanger


Fin tube heat exchanger is constructed with stainless steel tubes and aluminum spiral fins, boasting robust anti-corrosion properties and enhanced stability. The structural design of the fin tube is intended to enhance the heat exchange area, optimize efficiency in heat transfer, facilitate complete air exchange with the fin tube, and ultimately achieve water-saving operation of equipment during both dry cooling and wet cooling stages. It can also effectively eliminate the occurrence of "white smoke" during winter operation of the cooling tower, thus ensuring a favorable working environment for the equipment and prolonging its service life.

140x140


Stainless Steel Heat Exchange Coil


The high-quality heat exchange coil utilizes a stainless steel serpentine bending tube and a sturdy framework, ensuring superior thermal performance and full contact with spray water for efficient heat exchange and effective cooling. The stainless steel heat exchange pipes are not only resistant to corrosion, but also lightweight and recyclable.

 

140x140




PLC Electrical Control System


Automated operation is achieved through intelligent control systems, further reducing operation and maintenance costs.


300x200

Cellular Type Easy-to-detach PVC Drift Eliminator

Efficiently extracting airborne water droplets, small wind resistance and an impressive capture rate of 99.99%, thus guaranteeing optimal heat transfer performance.

 

300x200

Uniform Water Distribution

The strategically positioned Three-splashed-Nozzles, evenly water distribution under low pressure flow; Large caliber and three splashed type design, not easy to block, enhance spray coverage and guarantee continuous effective spraying, ensuring the efficient cooling performance of cooling tower.

300x200

Heavy-duty Structure

The design features a compact structure, utilizing high-quality galvanized steel plate and stainless steel bolt fastening. Furthermore, it has the option to be upgraded to an all-stainless steel structure or NWN-Armour anti-corrosion structure, providing enhanced resistance against corrosion and extending its service life.


Optional Various Additional Functions
Vibration Cut-off Switch/ Electronic descaler/ Water treatment equipment/ Anti-freeze automatic heating system etc.

 
140x140


Cost-effective Anti-Corrosion Solution
NEWIN NWN-Armour Anti-corrosion Technology

Products coated with NWN-Armour anti-corrosion coating exhibit outstanding resistance to corrosion, approaching the qualities of stainless steel. They serve as a cost-effective alternative to stainless steel.

 
 
Model Wet Cooling Free Cooling Fan Motor Spray Pump Total Dimension Weight
Fluid Flow Cooling Capacity Cooling Capacity Power Power L W H Shipping Operation
m³/h kW kW kW kW mm mm mm kg kg
NWN-GS-60-Z7-S 10 52  9.1  1.1*1 0.75 1800 900 3480 760 1180 
NWN-GS-90-Z7-S 15 77  9.4  1.5*1 0.75 1800 900 3480 810 1230 
NWN-GS-120-Z7-S 20 103  17.8  1.1*2 0.75 2300 1100 3320 1030 1810 
NWN-GS-180-Z7-S 30 155  22.8  1.5*2 1.1 2850 1100 3370 1320 2260 
NWN-GS-230-Z7-S 40 206  31.1  2.2*2 1.1 2850 1100 3580 1420 2460 
NWN-GS-290-Z7-S 50 258  31.9  3*2 1.1 2850 1100 3580 1520 2560 
NWN-GS-350-Z7-S 60 309  34.6  3*2 1.1 2850 1200 3740 1690 2880 
NWN-GS-450-Z7-S 80 412  74.4  3*3 2.2 4600 1450 3940 3290 4600 
NWN-GS-600-Z7-S 100 515  76.9  4*3 2.2 4600 1450 3940 3490 4900 
NWN-GS-750-Z7-S 125 644  94.8  7.5*2 2.2 4650 1750 4410 4100 6160 
NWN-GS-850-Z7-S 150 773  124.4  7.5*2 3 4650 2250 4540 4700 7440 
NWN-GS-1000-Z7-S 175 901  125.7  7.5*2 3 4650 2250 4710 4900 7740 
NWN-GS-1150-Z7-S 200 1030  171.9  11*2 5.5 6200 2250 4820 6030 10210 
NWN-GS-1300-Z7-S 225 1159  175.2  11*2 5.5 6200 2250 4820 6230 10510 
NWN-GS-1450-Z7-S 250 1288  197.2  15*2 5.5 6250 2500 5080 6780 11620 
NWN-GS-1750-Z7-S 300 1545  239.7  15*2 7.5 6250 3000 5180 7740 13510 

Note:
1. Standard Design Working Condition: Fluid in/out temperature: 35/30℃.
2. Standard design ambient wet/dry bulb temperature: 21/31℃.
3. Above data sheet based on 40% ethylene glycol solution fluid.
4. Please contact NEWIN sales representative if working condition not same as above standard design condition.
This table sample only contanins the data when issued, please do not use for engineering construction. Please further to confirm with sales and engineer about the detailed data before purchasing. If need muti-cells, please consult  the manufacturer to providethe solutions. NEWIN reserves the right to change the parameters or dimensions of the table without notice.

 

Please make sure your contact information is correct. Your message will be sent directly to the recipient(s) and will not be publicly displayed. We will never distribute or sell your personal information to third parties without your express permission.

Related Products