{"en":"Engineering And Construction","es":"Ingeniería y construcción","ru":"Инженерно - строительные работы","zh-cn":"工程建设"}

Under the climatic conditions of the project location, provide owners with cooling tower design under the latest technical standards.On the premise of meeting the requirements for use, save energy and water as much as possible.

Tecnología de enfriamiento mixto seco en enfriamiento húmedo En verano / temporada cálida, la temperatura de bulbo húmedo es relativamente alta, use enfriamiento húmedo para alcanzar la temperatura del agua de salida requerida por el cliente. En invierno / temporada fría, la temperatura de bulbo húmedo es baja, use enfriamiento seco solo para alcanzar la temperatura del agua de salida requerida por el cliente, la bomba de pulverización deja de funcionar para reducir el consumo de energía. Tecnología de enfriamiento mixto seco-húmedo en enfriamiento seco En circunstancias normales, utilice el enfriamiento adiabático en condiciones climáticas extremas para arrullar en seco. Para reducir la temperatura del agua de salida para garantizar el funcionamiento normal del enfriador y otros hosts en condiciones climáticas extremas, utilizando condiciones de trabajo adiabáticas para obtener una temperatura del agua de salida más baja que la temperatura de bulbo húmedo.  

Frequency conversion energy-saving control technology based on output constant temperature.
For the cooling system with strict requirements on outlet temperature,we provide PLC control system, with internal integrated frequency converter, adjust fan speed and pump flow to achieve the purpose of stable output.

Anti-icing automatic heating control technology
In winter of cold areas, suspend cooling tower working will cause the pool to freeze, and damage the water pump and pipeline equipment. Hanging ice on the cooling tower is easy to cause accidental injuries.
For this, we have designed a special anti-freezing device, through the automatic control to achieve the effect of never freezing.
Soft water / drinking water closed cooling design
For some high-end equipment or food equipment, to prevent pollution caused by heat ex-changer leakage, closed cooling system is recommended, pipeline and heat exchange adopt SUS304 / 316 to ensure clean water channel.

 

Nuestro servicio

Servicio

  • Contratación de proyectos
  • Ingeniería y Construcción
  • Diseño de modelado 3D
  • Mejora del rendimiento térmico
  • Renovación de la torre de enfriamiento
  • Reforma del ahorro de energía
  • Prueba de rendimiento
  • Procesamiento de reducción de ruido